System Start-Up

Chapter 4

4Ć5

Figure 1.17

System StartĆup Procedure for the 1770ĆM11 System

POWER

IN

OUT

BAUD RATE

1 2 3

SERIAL CHANNEL J22

MASS STORAGE SYSTEM

1770-M11 Mass Storage System - Back View

Select communication rate

Select position 1

Insert power cord

Both indicators remain off

11973

1.

Select the communication rate by sliding the BAUD RATE switch to:

Position

For Communication Rate

1

57.6kbaud for 10,000 ft (max)

2

115.2kbaud for 5,000 ft (max)

3

230.4kbaud for 2,000 ft (max)

2.

Select position 1 of the POWER switch. This initiates the following
indicator response:

POWER indicator lights green.

Micro-floppy drive indicator blinks twice.

Winchester drive indicator blinks twice.

Winchester drive indicator lights red.

Micro-floppy drive indicator blinks once.

Both the micro-floppy and Winchester indicators remain off.