Rockwell Automation 1771-SDN DeviceNet Scanner Module Installation Instructions User Manual

Page 38

Advertising
background image

Publication 1771-IN014B-EN-P - September 2001

38 DeviceNet Scanner Module Catalog Number 1771-SDN/C

The following information applies when operating this
equipment in hazardous locations:

Informations sur l’utilisation de cet équipement en
environnements dangereux :

Products marked “CL I, DIV 2, GP A, B, C, D” are
suitable for use in Class I Division 2 Groups A, B, C, D,
Hazardous Locations and nonhazardous locations only.
Each product is supplied with markings on the rating
nameplate indicating the hazardous location
temperature code. When combining products within a
system, the most adverse temperature code (lowest “T”
number) may be used to help determine the overall
temperature code of the system. Combinations of
equipment in your system are subject to investigation by
the local Authority Having Jurisdiction at the time of
installation.

Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne
conviennent qu’à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages
sur sa plaque d’identification qui indiquent le code de
température pour les environnements dangereux.
Lorsque plusieurs produits sont combinés dans un
système, le code de température le plus défavorable
(code de température le plus faible) peut être utilisé
pour déterminer le code de température global du
système. Les combinaisons d’équipements dans le
système sont sujettes à inspection par les autorités
locales qualifiées au moment de l’installation.

EXPLOSION HAZARD

Do not disconnect equipment
unless power has been removed
or the area is known to be
nonhazardous.

Do not disconnect connections to
this equipment unless power has
been removed or the area is
known to be nonhazardous.
Secure any external connections
that mate to this equipment by
using screws, sliding latches,
threaded connectors, or other
means provided with this
product.

Substitution of components may
impair suitability for Class I,
Division 2.

If this product contains batteries,
they must only be changed in an
area known to be nonhazardous.

RISQUE D’EXPLOSION

Couper le courant ou s’assurer
que l’environnement est classé
non dangereux avant de
débrancher l'équipement.

Couper le courant ou s'assurer
que l’environnement est classé
non dangereux avant de
débrancher les connecteurs. Fixer
tous les connecteurs externes
reliés à cet équipement à l'aide
de vis, loquets coulissants,
connecteurs filetés ou autres
moyens fournis avec ce produit.

La substitution de composants
peut rendre cet équipement
inadapté à une utilisation en
environnement de Classe I,
Division 2.

S’assurer que l’environnement est
classé non dangereux avant de
changer les piles.

WARNING

!

AVERTISSMENT

!

Advertising