8 SLC 500™ RTD/Resistance Input Module

Publication 1746-IN012B-EN-P - May 2001

Terminal Block Wiring and Removal

The RTD module contains an 18-position, removable terminal block. The terminal
pin-out is shown below.

Terminal Wiring

Terminal screws accept a maximum of two #14 AWG (2 mm

2

) wires. Tighten

terminal screws only tight enough to immobilize wires. Maximum torque on
terminal screws is 0.7 to 0.9 Nm (6 to 8 in-lb.).

ATTENTION

!

Disconnect power to the SLC before attempting to install,
remove, or wire the removable terminal wiring block.
To avoid cracking the removable terminal block, alternate the
removal of the terminal block release screws.

Terminal Block Spare Part

Catalog Number 1746-RT25G

Shield

Channel 0 RTD

Channel 0 Sense

Channel 0 Return

Shield

Channel 2 RTD

Channel 2 Sense

Channel 2 Return

Shield

Release Screw Max Torque

= 0.7 - 0.9 Nm (6 - 8 in-lbs)

Release Screw Max Torque =
0.7 - 0.9 Nm (6 - 8 in-lbs)
Shield

Channel 1 RTD

Channel 1 Sense

Channel 1 Return

Shield

Channel 3 RTD

Channel 3 Sense

Channel 3 Return

Shield

Advertising