Specifications A-13

Field Termination Plug
Specifications

Specifications for the Field Termination Plug are listed below.

Voltage Rating

28.8V dc maximum

Sensor and Adapter Current

2.5A maximum

Output Current

10A maximum

Sensor/Output Voltage

10-28.8V dc

Sensor/Output Power Connector

0.875 in male

Dimensions (H x D x W)

121 mm X 36.3 mm X 42 mm
4.75 in. X 1.43 in. X 1.65 in.

Environmental Conditions
Operational Temperature
Storage Temperature
Shock Operating
Non-operating
Vibration

-20 to 60°C (-4 to 140°F)
-40 to 85

°

C (-40 to 185

°

F)

30g peak acceleration, 11(±1) ms pulse width
50g peak acceleration, 11(±1) ms pulse width
Tested 5g @ 10-500 Hz per IEC 68-2-6

Conductors

See publication DN-6.7.2

Enclosure

Meets IP67

Agency Certification
(When product is marked)

c-UL-us

UL Listed Industrial Control Equipment,

certified for US and Canada
UL

UL Listed Industrial Control Equipment

CE

1

European Union 89/336/EEC
EMC Directive, compliant with:
EN 50081-2; Industrial Emissions
EN 50082-2; Industrial Immunity
EN 61326; Meas./Control/Lab., Industrial

Requirements

EN 61000-6-2; Industrial Immunity

C-Tick

1

Australian Radiocommunications Act,

compliant with:
AS/NZS 2064; Industrial Emissions

1. See the Product Certification link at www.ab.com for Declarations of Conformity, Certificates, and other

certification details.