10 XM Dynamic Measurement Module
Publication
ICM-IN002A-EN-P - March 2009
Set the Node Address
The module has a DIP switch for setting the network node address. DIP
switches 5 through 10 set the module’s node address using binary addressing.
The module is shipped from the factory with the node address set to 63 (as
shown below).
Follow the steps below to set the node address.
for the switch settings of an address.
2. Using a pointed tool, slide switches 5 through 10 to the appropriate
positions (1 or 0).
TIP
DIP switches 1 through 4 are not used.
TIP
The node addresses start with 1 for the module closest to the ACNR, and
increase for each consecutive module.
DYNAMIC MEASUREMENT
1440-DYN02-01RJ
Up position =1
Down position = 0