SECTION IV - INSPECTION FOR ILLUMINATED LEDs

THERE SHOULD BE A MINIMUM OF

THREE RED LEDs ILLUMINATED AND

OF THE THREE THERE MUST BE A “RHT”

OR “LFT”, PLUS A “FRT”, "MID" OR “RER”,

PLUS A “MOD” OR “SES”.

DO THE ABOVE CONDITIONS

EXIST?

NO

REPLACE THE EC-16

CONTROLLER

AND REPEAT THE “INITIAL START-UP

PROCEDURE”

GO TO SECTION V “TESTING

FOR POWER TO THE EC-16

CONTROLLER”

YES

USING THE TWO POSITIONING LEDs

(RIGHT/LEFT FRONT/REAR) GO TO

SECTION VIA “TESTING THE

MODULATOR” AND TEST THE

APPROPRIATE MODULATOR.

YES

USING THE TWO POSITIONING LEDs

(RIGHT/LEFT FRONT/REAR) GO TO

SECTION VIIA “TESTING THE WHEEL

SPEED SENSOR” AND TEST THE

APPROPRIATE SPEED SENSOR.

YES

NO

START HERE

NO

IS “MOD” LED ILLUMINATED

THE “SES” LED IS ILLUMINATED

NOTE RED “ECU” LED IN

EC-16

CONTROLLER

DIAGNOSTICS WINDOW.

IS THIS LED ILLUMINATED?

NOTE THE THREE ILLUMINATED LEDs

EC-16

CONTROLLER

DIAGNOSTIC DISPLAY

1 LED

FROM THIS GROUP

1 LED

FROM THIS GROUP

1 LED

FROM THIS GROUP

EC-16

CONTROLLER

DIAGNOSTIC DISPLAY

"ECU" LED ON?