Bendix Commercial Vehicle Systems EC-16 ANTILOCK CONTROLLER 4/08 User Manual

Page 22

Advertising
background image

22

SECTION VI A - TESTING THE MODULATOR

INSPECT CONNECTOR AND RECONNECT TO

EC-16

CONTROLLER. TURN IGNITION ON AND

PASS MAGNET OVER RESET ON EC-16

CONTROLLER. NOTE REACTION OF RED LEDs.

SAME RED LEDs

ILLUMINATED?

REPEAT “INITIAL START-UP

PROCEDURE.” IF THIS TEST STEP

HAS REPEATED TWICE - REPLACE

THE EC-16

CONTROLLER.

NO

YES

YES

NO

GO TO SECTION VI B AND

CONTINUE TESTING

NO

YES

F E D

C B A

1
2
3

K J H G F

E D C B A

H1

LEFT FRONT MOD. COMMON

F1

LEFT FRONT MOD. EXHAUST

G1

LEFT FRONT MOD. HOLD

C1

RIGHT FRONT MOD. COMMON

E1

RIGHT FRONT MOD. EXHAUST

D1

RIGHT FRONT MOD. HOLD

F1

LEFT REAR MOD. COMMON

D1

LEFT REAR MOD. EXHAUST

E1

LEFT REAR MOD. HOLD

A1

RIGHT REAR MOD. COMMON

C1

RIGHT REAR MOD. EXHAUST

B1

RIGHT REAR MOD. HOLD

1
2
3

REPLACE THE EC-16

CONTROLLER.

GO TO SECTION IV

“INSPECTION FOR

ILLUMINATED LEDs”

AND RETEST.

18 PIN CONNECTOR

30 PIN CONNECTOR

TURN IGNITION OFF. REFER TO

ILLUSTRATION, DISCONNECT WIRE

HARNESS CONNECTOR FROM

EC-16

CONTROLLER.

START HERE

ARE RESISTANCE

VALUES CORRECT?

ARE ANY RED LEDs

ILLUMINATED?

PROBE CONNECTOR WITH VOLT/OHM METER AND NOTE THAT

PROPER RESISTANCE VALUES ARE OBTAINED FOR MODULA-

TOR BEING TESTED. RESISTANCE VALUES HERE FOR BENDIX

®

M-21

MODULATOR.

HOLD TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO COMMON:

READ 3.5 TO 5 OHMS

EXHAUST TO HOLD:

READ 7 TO 10 OHMS

COMMON TO GROUND:

NO CONTINUITY

HOLD TO BATTERY POWER:

NO CONTINUITY

HOLD TO GROUND:

NO CONTINUITY

EXHAUST TO GROUND:

NO CONTINUITY