Controller – Bendix Commercial Vehicle Systems EC-16 ANTILOCK CONTROLLER 4/08 User Manual

Page 21

Advertising
background image

21

SECTION V - TESTING FOR POWER TO THE EC-16

CONTROLLER

VOLTAGE SAME AS BATTERY

VOLTAGE. MUST BE

BETWEEN 11 AND 17 VOLTS.

NO

YES

RECONNECT CONNECTOR TO EC-16

CONTROLLER. CHECK THE VEHICLE

WIRING FOR CONTINUITY. REFER TO

THE VEHICLE SERVICE MANUAL AND

CHECK THE BATTERY VOLTAGE.

REPAIR OR REPLACE WIRING AS

NECESSARY AND RETEST

REPEAT THE

“INITIAL START-UP

PROCEDURE”

START HERE

TURN IGNITION OFF, DISCONNECT 30 PIN

CONNECTOR FROM EC-16

CONTROLLER

REPLACE EC-16

CONTROLLER

A1

A2

A3

K2

K3

30 PIN CONNECTOR

B1

TURN IGNITION ON AND MEASURE

VOLTAGE BETWEEN BATTERY PINS B1,

K2, K3 AND GROUND PINS A1, A2, A3

ON WIRE HARNESS CONNECTOR

Advertising