4.1 Configuring & Customizing Your

SmarTire Trailer-Link

System

During the installation process, the default settings for SmarTire Trailer-Link

TPMS should be customized to the trailer by the installer. Using the SmarTire

Trailer-Link Diagnostics Software within Bendix

®

ACom

®

Diagnostics 6.6 (or

higher), alert thresholds can be made more or less sensitive and system

settings can be adjusted to accommodate trailer changes and use.

Replacing trailer tires or installing the system on a new trailer may also require

adjustment of pre-configured settings. The following section describes how

to adjust the pre-configured settings of your SmarTire Trailer-Link TPMS.

4.1.1 Pre-Configured Settings
Generally, the SmarTire Trailer-Link TPMS is pre-configured with the default

settings listed below. Depending on your vehicle, your system may have a

different initial setup.

● Cold Inflation Pressure (CIP):

◊ 4-Wheel (2-axle Configuration)

• Trailer Axle 1&2: 100 PSI (6.89 bar)

◊ 8-Wheel (2-axle Configuration)

• Trailer Axle 1&2: 100 PSI (6.89 bar)

● First Alert Level (FAL) Pressure Deviation Alert: CIP ±15% (temperature

compensated)

● Second Alert Level (SAL) Critical Low Pressure Alert: CIP -20%

● High Temperature Alert: 185°F (85°C)
Default cold inflation pressure settings should always be customized to the

trailer. Check the trailer’s placard or the industry published load inflation

table to determine the recommended cold inflation pressure settings. Bendix

recommends setting the Second Alert Level (SAL) critical low pressure alert

at 20% below the recommended cold inflation pressure for your trailer. Bendix

also does not recommend changing the First Alert Level (FAL) pressure

deviation alert setting as well as the High Temperature Alert setting of 185F.

To make changes to the FAL, SAL, and High Temperature settings refer

to the SmarTire Trailer-Link Diagnostics settings within Bendix ACom

Diagnostics. For programming sensor IDs and changing the axle CIP using

the Maintenance Hand tool, see the instructions that follow. These instructions

can also be found in the Maintenance Hand tool manual (BW2809).