7.1.4 Q: What additional diagnostic information is available?
A: The external LED part # K075866 is connected via the cable harness as a

separate plug. Please refer to Section C, 4.0, step 7 for details on installation

and location of this LED. The LED functions as described in the table below.

Flashing with pattern will have periods of 0.3 second on and 0.3 second off

repeating every 6 seconds. The number of high pulses in each 6–second

window will be determined by a code. For example if the flash code is 2, the

pattern will be 0.3 second on, 0.3 second off, 0.3 second on, 5.1 seconds

off and repeating.

Alarms

Priority External LED

See

Note

No Alarms

0

Off

-

Second Level Low Pressure (SAL)

6

Pattern flashing

code: 4

-

SAL Cleared

0

Off

-

First Level High Pressure (FAL_H)

4

Pattern flashing

code: 2

-

First Level Low Pressure (FAL_L)

3

Pattern flashing

code: 2

-

FAL Cleared

0

Off

-

High Temperature

7

Pattern flashing

code: 5

-

High Temperature Cleared

0

Off

-

Sensor Diagnostic Trouble Code (DTC) Set

2

Pattern flashing

code: 1

1

Sensor DTC Cleared

0

Off

-

ROM To Both Copy Performed

10

Pattern flashing

code: 7

2

Set Up DTC

5

Pattern flashing

code: 3

3

Set Up DTC Cleared

0

Off

-

Factory To Custom Copy Performed

9

Pattern flashing

code: 7

2

Custom To Factory Copy Performed

8

Pattern flashing

code: 7

4

Watchdog Reset

11

Pattern flashing

code: 8

5

Sensor Battery Low Alert

1

Pattern flashing

code: 6

-

Table 5