Bunn LCR-3 User Manual

Page 13

Advertising
background image

13

ENTER PASSWORD

(-) 0 (+)

SET PASSWORD ?

(-) 0 (+)

2 OR 3 PRODUCTS?

(2) EXIT (3)

SELECT UNITS

ENG EXIT METRIC

REFRIGERATION ?

ON EXIT OFF

DEICE CYCLE TIME

(-) 120 MIN (+)

RINSE ALARM ?

NO EXIT YES

RINSE TIME ?

(-) 12 HRS (+)

RINSE LOCKOUT ?

NO EXIT YES

The following functions can be Password Protected. If you wish to prevent others from accessing these functions,

enter a 4 digit code of your choice. Record your password code [_ _ _ _], as you will need it to access these

functions in the future.

Use the (+) or (-) buttons to

enter password.

Use the (+) or (-) buttons to

change the password.

Select the number of products

to be dispensed

Select the preferred units.

Select OFF to disable the

Refrigeration system

Select the time delay between

automatic deicing of the

cabinet

Select (YES) or (NO)

Use the (+) or (-) buttons to

adjust Rinse Alarm delay.

Select (YES) to enable

Enter the access Code to view the remaining

functions. Factory Default = 0.

Enter your own Code to prevent access to the

remaining functions. [0 to 9999]

Used to switch from standard 3 products to 2

products w/Autoswitching of the Left and Middle

Bibs.

Used to select the preferred units of measurement.

(Oz., Gal, deg F) or (mL, L, deg C)

Select OFF to temporarily override a cooling system

fault and allow the machine to dispense coffee.

If ice builds up on the evaporator - decrease the

delay. If the cabinet is not cold enough - increase

the delay.

Factory Default=120 (2 hrs)[min=30, max=180]

Selecting Yes will enable the Rinse Alarm function,

(see Rinse Alarm)

Enter the desired time between required Rinse

Cycles in hours. [8 to 24 hrs]

Select YES to Lockout dispensing until the Rinse

Alarm has been cleared. Default is NO.

LCD DISPLAY

ACTION

DESCRIPTION

PROGRAMMING (Continued)

41129 071409

TANK TEMP 190

(-) EXIT (+)

READY TEMP 180

(-) EXIT (+)

CABINET TEMP 38

(-) EXIT (+)

Use the (+) or (-) buttons to

adjust the target Temp.

Use the (+) or (-) buttons to

adjust the target Temp.

Use the (+) or (-) buttons to

adjust the target Temp.

Sets the water Tank temperature:

(120 - 200°F) or (49 - 93°C)

Sets the hot water Ready temperature:

Typically set to the min. desired dispense temp.

Sets the Chilled cabinet target temperature:

(38 - 50°F) or (3 - 10°C)

LCD DISPLAY

ACTION

DESCRIPTION

If ON

If YES

If NO

to Next Page