Bunn LCR-3 User Manual

Page 23

Advertising
background image

23

Troubleshooting (Continued)

Service Required

Service Required

Replace Tubing

1. Pump Motor failure

2. RPM Sensor failure

3. Tubing pinched in rollers

____ PUMP FAULT

CHK PUMP WIRING

CHK RPM SENSOR

CHK TUBING AREA

Check Pump & Flow Rate Calibration, refer

to Field Calibration Procedures

The calculated Target RPM for the

pump indicated is out of range

____ TARGET RPM

TOO LOW !!

Service Required

Service Required

Service Required

1. Refill valve stuck open

2. Faulty refill probe

3. Faulty overflow switch

OVERFLOW

FAULT

Service Required

Service Required

Service Required

1. Tank Heater failure

2. Triac failure

3. Tank Temp. sensor failure

HEATING TIME

TOO LONG

CHECK HEATING

CIRCUIT

Screen Displayed

Possible Cause

Troubleshooting Procedures

Check water supply valve

Service Required

1. Water shut off to dispenser

2. Inlet Solenoid Valve failure

FILL TIME

TOO LONG

CHECK WATER

SUPPLY

Service Required

Service Required

1. Corresponding Temperature

Sensor Probe wire(s) broken

or disconnected

2. Corresponding Temperature

Sensor Probe wire(s) shorted

to housing, or to each other.

TANK SENSOR

OUT OF RANGE

CHECK FOR BAD

CONNECTIONS

CHECK WIRE

FOR SHORTS

41129 052208