LCD DISPLAY

ACTION

DESCRIPTION

PROGRAMMING (Continued)

XXOVERFLOW > 155

(-) EXIT (+)

XX REFILL -> 155

(-) EXIT (+)

WTR START DELAY

(-) .15SEC (+)

WTR STOP DELAY

(-) .15SEC (+)

TEST SWITCHES ?

UseSwitchToTest

TEST REFILL ?

EXIT YES

TEST HEATER ?

EXIT YES

ENTER ASSET #

(-) 000000 (+)

SERIAL #

LCR 0000000

VIEW FAULTS?

(-) EXIT (+)

LATEST FAULT

NO FAULTS

FACTORY DEFAULTS

NO

YES

Use the (+) or (-) buttons to

adjust Overflow threshold

Use the (+) or (-) buttons to

adjust Refill threshold

Use the (+) or (-) buttons to

adjust delay time

Use the (+) or (-) buttons to

adjust delay time

NONE

Momentarily depress (YES)

Momentarily depress (YES)

Use the (+) or (-) buttons to

enter the ASSET NUMBER

NONE

Select (+) to view the Fault

Conditions

Use the (+) or (-) to scroll

through the Faults

Select (YES) or (NO)

Used to set the Conductance Threshold for the

Tank Overflow Probe

Used to set the Conductance Threshold for the

Tank Refill Probe.

Dispense Valve ON Delay. Eliminates weak mix

at the beginning of a dispense.

Dispense Valve OFF Delay. Flushes the mix

chamber at the end of a dispense.

Switch Diagnostic: Activate switches separately to

test. Display will indicate which Switch has been

activated. NOTE: Door Interlock switch must be

held closed.

Refill Valve Diagnostic: Press YES to momentarily

energize the Solenoid. CAUTION: Inlet Valve will

open and water will flow, if connected and turned

ON.

Tank Heater Diagnostic: Press YES to momentarily

energize the Tank Heater Circuit. CAUTION: AC

power will be applied to the Tank Heater Circuit.

Allows the user the option of entering an Asset

Number. Default is 000000

Displays the manufacture’s Serial Number (should

be identical to the Serial Number on the Data

Plate)

This unit stores the last 3 Fault Conditions in

memory for diagnostic purposes.

Displays up to 3 FAULT Conditions or NO

FAULTS, if nothing has failed since the last “Reset

Defaults”.

CAUTION: Selecting YES will RESET all Program-

ming Functions to the Factory Default settings

41129 021709