Bunn LCR-3 User Manual

Page 22

Advertising
background image

22

Check Pump & Flow Rate Calibration, refer

to Field Calibration Procedures

The calculated Target RPM for

the pump indicated is out of

range

____ TARGET RPM

TOO HIGH !!

Replace BIB, see Loading the Concentrate

Check BIB Connector Fittings

Check Tubing Installation

Check Empty BIB Threshhold, see Field

Calibrating the Epmty BIB Warning

Concentrate BIB is empty.

BIB not properly connected.

Tubing kinked or blocked.

Empty BIB Threshhold too high.

XXXX BIB EMPTY

Replace BIB Soon

Rinse Dispenser, see Rinse Procedure

Replace BIB, see Loading the Concentrate

Rinse Alarm Time Interval has

expired

RINSE REQUIRED

Wait for water temp to rise

Check Ready Temp. threshhold setting

Service Required

Water temp is below the preset

READY temp

HEATING

Please Wait!

Check Master ON/OFF Switch

Check Power Cord & Circuit Breaker

Service Required

No Power to the Dispenser

NO DISPLAY

Troubleshooting

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic

Technical Service Department.

• Only qualified service personnel should perform inspection, testing, and repair of electrical equipment.

• Shorting the terminals or the application of external voltages to electronic components may result in component

or circuit board failure.

• Intermittent operation of electronic circuit boards is unlikely. board failure will normally be permanent. If an

intermittent condition is encountered, the cause will likely be a switch contact or a loose wire connection at

a terminal or crimp.

• Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are

energized for more than ten minutes without a supply of water.

• The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will

help avoid twists and kinks in the tubing.

• Make certain that all plumbing connections are sealed and all electrical connections are tight and isolated.

• This dispenser is heated at all times. Keep away from combustibles.

WARNING:

• Exercise extreme caution when servicing electrical equipment.

• Disconnect the brewer from the power source when servicing, except when electrical tests are specified.

• Follow recommended service procedures.

• Replace all protective shields or safety notices.

Screen Displayed

Possible Cause

Troubleshooting Procedures

41129 052208