Record run, Free run, Free run auto mute – Sound Devices 633 User Manual

Page 54: 24h run (24 hour run), 24h run auto mute, External timecode, External timecode auto-record, External timecode continuous, External timecode auto-record continuous, Timecode

Advertising
background image

Record Run

Rec Run - Generator mode. The 633 sends running timecode while recording and stationary time-

code while not recording. Timecode in this mode defaults to the last stationary value at power-up.

When switching to Record Run from another mode, the internal generator will stop at the last num-

ber generated. A user-defined value can be jammed into the internal generator from the Setup Menu

option TIMECODE > Set Generator TC.

Free Run

Generator mode. Time code runs continuously. The value can be set by “jamming value” in the Setup

Menu option TIMECODE/SYNC > Jam Menu or by manually setting a value from the Setup Menu

option TIMECODE/SYNC > Set Generator TC.

Free Run Auto Mute

Functions the same as Free Run mode except timecode signal is muted from the LEMO output when

the 633 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable

(e.g. Multi-camera shoots).

24h Run (24 hour Run)

Generator mode. Time code runs continuously. When this Time Code Mode is selected or when

the time/date is altered, the time code value is jammed to the value of the time-of-day clock. The

value can be set by “jamming value” in the Setup Menu option TIMECODE/SYNC > Jam Menu or by

manually setting a value from the Setup Menu option TIMECODE/SYNC > Set Generator TC.

24h Run Auto Mute

Functions the same as 24h Run mode except timecode signal is muted from the LEMO output when

the 633 is in stopped mode. This allows rec-run functionality when Rec Run mode is not suitable

(e.g. Multi-camera shoots).

External Timecode

Ext-TC - Reader mode. The internal timecode generator follows an external timecode signal appear-

ing at the timecode input. If the external timecode is removed the internal generator stops as well.

Recording is triggered manually with the Transport Control.

External Timecode Auto-Record

Ext-TC Auto-Rec - Reader mode. The internal timecode generator follows an external timecode sig-

nal appearing at the timecode input. If the external timecode is removed the internal generator stops

as well. The 633 automatically begins recording when running timecode is sensed. When stopped

timecode is sensed, recording stops. (

See “Meter Ballistics”, page 20

)

External Timecode Continuous

Ext-TC/Cont - Reader mode. The internal timecode generator follows an external timecode signal

appearing at the timecode input. If the external timecode is removed the internal generator continues

to run to preserve continuous timecode. Recording is triggered manually with the Transport Control.

External Timecode Auto-Record Continuous

Ext-TC Auto-Rec/Cont - Reader mode. The internal timecode generator follows an external timecode

signal appearing at the timecode input. If the external timecode is removed the internal generator

continues to run to preserve continuous timecode. The 633 automatically begins recording when run-