System, Se tup menu – Sound Devices 633 User Manual

Page 68

Advertising
background image

#

Parameter Name

Description

Options

6

Scene Increment Mode

Selects which format the scene increments will

use. To quickly increment a scene name press

and hold the Headphone Encoder then slide the

Transport Control right (Fast Forward)

» Disabled
• Character
• Numeric

7

Take Reset Mode

Defines when take numbers are reset. Reset

brings take number to <1>

• Never
• Scene Change
• Daily Folder Change

» Either Scene or Daily

8

File Playback Mode

Determines what (If any) playback action the 633

will perform upon reaching the end of a file during

playback.

» Play Once
• Play All
• Repeat One
• Repeat All

9

Default Playback Card

The source media that files will be played from

when playback is initiated.

» CF
• SD

10

Erase/Format CF

Formats CF card to FAT32 (32 GB or less) or

exFAT (greater than 32 GB) file system.

11

Erase/Format SD

Formats SD card to FAT32 (32 GB or less) or

exFAT (greater than 32 GB) file system.

System

#

Parameter Name

Description

Options

1

Slate Mic

Enable or disable the internal slate microphone.

• Off

» On

2

Slate & Tone Routing

Displays the Slate and Tone Routing screen where

the slate mic and tone signal can be routed to various

destinations.

3

Tone Level

The level of the 633’s internal tone generator.

• 0-20 dBu (1 dBu increment)

» 0 dBu

4

Tone Frequency

The audio frequency of the 633’s internal tone gen-

erator.

• 100-10000 Hz (10 Hz increment)

» 1000 Hz

5

Tone Mode

Continuous tone generates tone a the set tone level

to all bus tracks. L Ident mode pulses the amplitude of

tone to the Left channel of the Master Bus by -20dB.

» Continuous
• L Ident

6

Warning Bell Level

The level of warning bell signals in the Headphones.

• Off, -60 to -12 dBFS

(1dB increment)

» -30 dBFS

7

Record/Stop Bell

Alerts the user with one beep at the start of recording

and two beeps when the recording is stopped

• Off

» On

8

Meter Ballistics

Selects among the two different meter ballistics set-

tings.

• VU Only

» Peak + VU
• Peak Only

9

Meter Peak Hold Time

Adjusts the duration for which the peak indicator stays

illuminated.

» 1 sec
• 2 sec
• 3 sec
• 4 sec
• 5 sec
• Infinity
• Off

10

Meter Display Style

The visual style of the meters. Segmented shows

individual blocks separated by gaps and Solid shows

a solid bar.

» Segmented
• Solid

633 User Guide and Technical Information

62

v. 1.02

Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.

Se

tup Menu

Advertising