3 performance charts – Trebor 110E User Manual

Page 10

Advertising
background image

PAGE 10

MODEL 110E PUMP OPERATION / MAINTENANCE MANUAL

White arrow on top of knob indicates approximate cycle time in seconds.

Rotate CW to slow cycle rate.

Rotate CCW to increase cycle rate.

NOTE: Operate pump at slowest possible cycle rate that will deliver desired flow.
This will extend pump diaphragm life!

3.3 PERFORMANCE CHARTS

Pumping capacity is a function of air supply pressure and volume, suction head,
suction line restrictions, discharge head, discharge line restriction, and fluid
specific gravity and viscosity.

Air Supply

Pressure

(PSIG)

Discharge

Fluid

Pressure

(PSIG)

Air

Used

(SCFM)

Cycles

Per

Minute

Displacement

IN

3

Per

Cycle

20

0

2.0

210

4.1

20

10

1.7

125

3.7

30

0

5.0

245

4.1

30

15

3.0

145

3.8

40

0

5.2

255

4.3

40

20

4.2

160

3.9

50

0

6.9

265

4.4

50

25

5.9

175

4.1

60

0

8.5

290

4.2

60

30

7.4

180

4.1

Table 1: Consumption / Efficiency

Figure 3-1: Pressure & Capacity Chart

NOTE: Test information is based on specific conditions and limited sampling.
Use for general reference only.

Advertising