MODEL 110E PUMP OPERATION / MAINTENANCE MANUAL

PAGE 9

3

START-UP

Pump air supply pressure should be regulated.

Open the fluid suction (IN) line valve, if necessary.

Open the fluid discharge (OUT) line valve, if necessary.

Start with air regulator at low (> 15 psi) pressure setting. Increase pressure

to attain desired flow, up to the maximum rating (See Section 3.2).

Table 1: Consumption / Efficiency can be used to determine approximate air

consumption.

Refer to Troubleshooting Section 5, if pump fails to start.

ATTENTION: Prolonged periods (> 5 minutes)

of dry running will damage critical

internal pump parts.

CAUTION: When handling potentially dangerous fluids under pressure,

the pump and its fittings should be placed in an enclosure.

3.1 PNEUMATIC OSCILLATOR/CONTROLLER CYCLE RATE

(PC10)

Applications with low flow or highly viscous fluid may require a slower cycle rate
for increased efficiency. A slower cycle rate will also decrease air consumption.

3.1.a Adjustment Instructions for Trebor Pneumatic Oscillator

Remove access plug from the pump control module cover.

Rotate adjustment knob with screwdriver.

Rotate CW (clockwise) to slow cycle rate.

Rotate CCW (counter-clockwise) to increase cycle rate.

Re-install access plug.

NOTE: The TREBOR Pneumatic Oscillator comes pre-set from the factory to
meet the flow requirements in most applications.

3.2 ELECTRONIC OSCILLATOR/CONTROLLER CYCLE RATE

(PC5)

Applications with low flow or highly viscous fluid may require a slower cycle rate
for increased efficiency. A slower cycle rate will also decrease air consumption.

3.2.a Adjustment Instructions for Trebor Electronic Oscillator