Printer Adjustments

54

Sensor Adjustments and Calibration

The sensing level of both the transparent (see thru) and reflective sensors is
adjusted separately and independently. Firstly, the sensor type must be
selected using the Sensor Method Selection shown below. Then the
adjustment and calibration of the sensor can be made.

The front sensor or adjustable sensor is selected using the Adjustable sensor
on the sub menu that is in Page Setup on the main menu. (See “Chapter 2.
Printer Operation”). The adjustable rear sensor is set by Factory Default.

Entering Sensor Adjustment Mode

1. Turn on the power while pushing the PAUSE key, FEED key, and

STOP key simultaneously.

STOP

FEED

PAUSE

Power Switch

2. After “Sensor Cal Mode” lights up, release the keys to change

the printer to sensor adjustment setting mode.

Quick Sensor Selection Method
(Transparent

Reflective)

To switch from transparent to reflective sensor, hold down the MENU key
and then press the STOP key. Each time you press the STOP key, you switch
to back and forth between the two sensor types.
If the transparent sensor is selected, “See Through” is displayed and the
buzzer sounds once. If the reflective sensor is selected, “Reflect” is displayed
and the buzzer sounds twice.

POWER

ERROR

Sensor Cal Mode

See Through

POWER

ERROR

Sensor Cal Mode

Reflect

Installing the Media
(p.25, p27)

3

Printer Adjustments

STOP

MENU

Hold

Press/Release