INSTALLATION AND OPERATION MANUAL

Models MF3700, MF3800

Page 15

800-345-6007

CumberlandStoveWorks.com

VENT TERMINATION CLEARANCES

CLEARANCE

9 inches

Clearance below or beside any door or window
that opens.

9 inches

Clearance above any door or window that
opens.

3 feet

Clearance from any adjacent building.

7 feet

Clearance from any grade when adjacent to
public walkways.

2 feet

Clearance above any grass, plants, or other
combustible materials.

3 feet

Clearance from any forced air intake of any
appliance.

2 feet

Clearance below eaves or overhang.

1 foot

Clearance horizontally from combustible
wall.

3 feet

Clearance above the roof.

2 feet

Clearance above the highest point on the roof
within 10 feet.

VENTING INSTALLATION EXAMPLES

Figure 21: STRAIgHT INSTALLATION
Inside Vertical Rise, Horizontal Termination

Figure 20: STRAIgHT INSTALLATION
Outside Vertical Rise, Through Wall Installation

INSTALLING REMOTE THERMOSTAT

The MF Parlor Stove can be run thermostatically by
purchasing any thermostat (sold separately) that uses a
mechanical switch. This step is optional and not required
for MF Parlor Stove to operate.
Mount thermostat according to manufacturer specifications.
Using a small flat head screwdriver, tighten remote
thermostat wires into pins 7 and 8.

SEE FIGURE 1.

remote

thermostat

terminals

Figure 19: Remote Thermostat Terminals