INSTALLATION AND OPERATION MANUAL

Models MF3700, MF3800

Page 6

800-345-6007

CumberlandStoveWorks.com

Figure 1: High limit Reset Button in Back Panel

AUTOMATIC SAFETY FEATURES

Power outage

During a power outage, the stove will shutdown safely.
It will not automatically restart when the power returns.
If the stove is still at operating temperature when power
returns, the convection fan will vent the remaining heat out
of the stove. See “Lighting Instructions” section for more
information.

overheating

Over-Fire Protection: If the stove is being over-fired or
burning too hot, the high limit switch will automatically shut
down the stove to avoid damage to components. Allow the
stove to cool at least one hour before relighting. The high
limit switch is located behind the right access panel. To
reset the high limit switch, press the square button in the
middle of the switch.

CAUTION

Installation and repair of this parlor stove should be

done by a qualified service person. The appliance
should be inspected before use and at least annually
by a qualified service person. It is imperative that
control compartments, fire box, and circulating air
passageways of the stove be kept clean.

The operation of exhaust fans such as bathroom

fans, attic fans, etc., might starve the parlor stove
of combustible air creating a negative pressure in
the room. Provide adequate ventilation of the room
accompanying the parlor stove. If not, the pressure
switch may shut off operation of the parlor stove.

The moving parts of this stove are propelled by

high torque electric motors. These parts can cause
severe damage to body parts that get near them.
Keep all body parts away from auger and fans while
the stove is plugged into an electrical outlet. These
moving parts may begin to move at any time the
stove is plugged in.

If the electrical power fails while the stove is hot,

keep all stove doors closed.

Vent surfaces can get hot enough to cause burns if

touched. Noncombustible shielding or guards may
be required.

Install vent at clearances specified by the vent

manufacturer.

All venting joints, whether vertical or horizontal,

should be made gas-tight with recommended
sealants specified by vent manufacturer.

According to HUD (Housing & Urban Development)

requirements, when installed in a mobile home, this
stove must be grounded directly to the steel chassis
of the mobile home and bolted to the floor. Direct
air access must be provided—use a Fresh Air Kit.

For use in the United States. Approved for

installation in mobile homes.

Cumberland Stove Works, manufacturer of this

appliance, reserves the right to alter its products,
specifications and/or price without notice.

WARNING

IF THE ELECTRICAL POWER FAILS ANY TIME WHEN
THE STOVE IS HOT, kEEP ALL STOVE DOORS
CLOSED.
THE AUTOMATIC SAFETY FEATURES MUST NOT BE
BYPASSED.
WHEN RESETTING THE HIGH LIMIT, NEVER USE ANY
CONDUCTORS AS THIS COULD CAUSE ELECTRICAL
SHOCk AND/OR DAMAGE TO STOVE.

reset button

DETAIL A