TROUBLESHOOTING GUIDE

Unplug stove before performing any maintenance.

WARNING

NEVER SERVICE OR TOUCH THE FEED AUGER WITH
THE STOVE PLUGGED IN.

Contact service provider if above remedies fail. Contact your dealer or call CSW customer service at 800-345-6007.
WARNING! Negative pressure in a home is a serious issue. If there is a problem, the stove should be installed with a
Fresh Air kit (not included).

Problem

Display Status

Possible causes

Remedy

Stove Will Not Feed Pellets

NO READINg

No power

Check to see if stove is plugged
in

Check communication cable

Check electrical outlet for power

Check fuse on incoming red
power wire

Defective control head

Test and replace control head if
needed

NORMAL READINg

Hopper is empty

Add fuel to hopper

Hopper lid is open

Close hopper lid

Pellet and/or auger jam

Check auger for fines or pellet
jam

Auger motor failure

Replace auger motor

Hopper switch failure

Bypass switch to test. Replace
hopper switch if needed

Problem

Display Status

Possible causes

Remedy

Fire goes Out or Stove Shuts
Down

LOSS OF FIRE
OFF TO RESET

Hopper is empty

Add fuel to hopper

Poor quality fuel

Change fuel supplier/moisture
test corn

Power supply interrupted

Check power supply. go through
re-ignite sequence

Plugged firepot

Clean firepot. Clear all holes of
ash or debris

OVERTEMP RESET SWITCH

Overtemp

Allow stove to cool and reset
switch

Loose connection on spade
terminal

Check connections on switch
and/or lower plug on IM

AUgER OVERTEMP

Overtemp

Allow stove to cool and reset fuel
shutoff.

Loose connection on spade
terminal

Check connections on switch
and/or lower plug on IM

VACUUM FAULT
CHECK SEALS

Inadequate door seals

Check that rope seals are in
working condition

Front door is ajar

Close door securely

Ash pan is ajar

Secure ash pan in its proper
position

Vacuum switch hose is loose/
disconnected, or switch is broken

Make sure vacuum switch hose is
attached to the switch. Replace
switch if necessary.