Installation and operation manual – Cumberland Stove Works MF3700 User Manual

Page 25

Advertising
background image

INSTALLATION AND OPERATION MANUAL

Models MF3700, MF3800

Page 5

800-345-6007

CumberlandStoveWorks.com

Problem

Display Status

Possible causes

Remedy

Stove Will Not Light

NORMAL READINg

Hopper is empty

Add fuel to hopper

Plugged firepot

Clean firepot. Clear all holes of
ash or debris.

Igniter slipped out of torque arm

Push igniter back into place

Igniter failed

Test igniter output leads on IM.
Confirm air pump operation.
Replace igniter if needed.

No power to igniter

Replace IM

NO PROOF OF FIRE
PUSH “ON” TO START

Igniter failed

Test igniter output leads on IM.
Confirm air pump operation.
Replace igniter if needed.

Pot Loading

NORMAL READINg

Plugged firepot

Clean firepot. Clear all holes of
ash or debris.

Poor quality fuel

Change fuel supplier/moisture
test corn

Firepot misaligned

Make sure firepot is aligned
properly and that there is no
unburned pellets obstructing
proper alignment of firepot.

Problem

Display Status

Possible causes

Remedy

Lazy Flame

NORMAL READINg

Poor quality fuel

Change fuel supplier/moisture
test corn

Firepot and plate require cleaning Clean firepot and plate. Clear all

holes of ash or debris.

Firepot misaligned

Make sure firepot is aligned
properly and that there is no
unburned pellets obstructing
proper alignment of firepot.

Fireplate in backwards

Adjust fireplate for correct
positioning. Fireplate notches
should always face towards the
front door of the stove.

Smell of Smoke in Room

NORMAL READINg

Exhaust vent is not sealed
properly

Seal all joints of exhaust vent
with high-temperature silicone
sealant.