5 duplex lube oil filter system, 6 lube oil vent coalescer, Figure 11 – CAT Titan 250 User Manual

Page 26: Typical lube oil system

Advertising
background image

Turbomachinery Package Specification

Titan

250 Generator Set

fire, control system failure, emergency stop, or if a turbine over-speed is detected by the
backup system.

8.1.5

Duplex Lube Oil Filter System

The duplex lube oil filter system is supplied with a filter transfer valve and filter differential
pressure indication with alarm. The transfer valve allows a filter transfer to be performed
while the gas turbine is running. The lube oil filter system is contained completely within
the skid. The interconnect piping between the skid edge and the offskid oil cooler, if
applicable, is not provided.

8.1.6

Lube Oil Vent Coalescer

An offskid lube oil vent coalescer is provided to remove oil vapor from the lube oil tank
vent airflow. The coalescer drains trapped oil vapor back to the lube oil tank and allows
the remaining vent airflow to exhaust to the atmosphere. A tank overpressure alarm and
shutdown are also included. The lube oil vent coalescer is loose shipped for offskid
installation by others.

DUPLEX

LUBE OIL

FILTER

SYSTEM

DPT

LUBE OIL

COOLER

COOLER

CONTROL VALVE

MAIN LUBE

OIL PUMP

PRE/POST

PUMP

BACKUP

PUMP

GENERATOR

COUPLING

GEARBOX

FG

FG

FG

FG

SCAVENGE LUBE OIL PUMP

(MARINE APPLICATIONS)

RT

RT

THRUST

BEARING

PT

RT

FLAME

ARRESTER

VENT

DEMISTER

PT

LT

LEGEND

DPT

DIFFERENTIAL PRESSURE TRANSMITTER

FG

FLOW GAUGE (SIGHT GLASS)

LT

LEVEL TRANSMITTER

RT

TEMPERATURE DEVICE (RTD)

PT

PRESSURE TRANSMITTER

FILTER

GAS PRODUCER SHAFT

LUBE OIL TANK