Turbomachinery Package Specification

Titan

250 Generator Set

• Graphics in a separate window for simultaneous viewing of text with associated

illustration

• PDF version for printing

17.5.5 Service Parts List

Identifies operational service parts and tooling. Once engineering has been finalized and
manufacturing bills are available, Solar's Service Parts department creates a detailed
listing of service parts from the actual equipment manufacturing bills of material.

Table 14. Preservation, Installation, and Documentation Specifications

Mechanical Installation Requirements

Mounting

Space Between Units In Multiple-Unit
Installations

A Minimum of 2.5 m (8 ft)

Lube Oil Cooler(s)

Top of The Lube Oil Cooler(s)

Not Be More Than 9 m (30 ft) Above The Bottom of
The Package Frame, See Note (a)

Total oil volume of “Outgoing and Return”
Lines

1282 L (340 gal)

Total Combined Pressure Drop of The
Supply and Return Lines and Lube Oil
Cooler(s)

Should Not Exceed 345 kPag (50 psig)

Start, Fuel, Lube, Air/Drain System Schematics

Compliance

American National Standards Institute (ANSI) Y32.10

Solar’s Applicable Engineering Specifications

ES 9-4

Interpretation of Drawing Requirements

ES 9-76

Traceability Requirements Critical Parts, Engine and Related Systems

ES 2231

Standards and Practices for The Design and Installation of Cable Channels and TC
Rated Cables Installed In Class 1, Division 2 Hazardous Areas

Solar’s Applicable Product Information Letters

PIL 184

Documentation for New Equipment

PIL 097

Package Preservation and Preparation for Shipment

Notes

:

(a)

This is to prevent oil tank flooding in the event of a drain back.

© 2008 Solar Turbines Incorporated. All rights reserved.