Turbomachinery Package Specification

Titan

250 Generator Set

Figure 11. Typical Lube Oil System

8.1.7

Lube Oil Vent Flame Arrestor

The lube oil vent flame arrestor prevents an ignition source from entering the lube oil
tank. The flame arrestor is loose shipped for offskid installation by others.

8.1.8

Lube Oil System Options

Lube Oil Cooler

An air-to-oil type cooler is available to provide oil cooling for the gas turbine and the
driven equipment. The cooler is sized for specified heat loads and ambient temperatures
and is designed for a 4.4°C (40°F) approach temperature. The cooler is loose shipped for
offskid installation by others.

Lube Oil Immersion Tank Heater

The lube oil tank immersion heater ensures the lube oil tank temperature is adequate for
starting in cold conditions. The tank heater also facilitates a short lube oil temperature
warm up period after a cold start. Electrical supply contactors are not included.

Table 6.

Lubrication System Specifications

Main Lube Oil Pump

Pump Type

Engine-Driven Rotary Screw

Flow

1999 lpm (528 gpm)

Discharge Pressure

690 kPag (100 psig), See Note (a)

Pre/Post Lube Oil Pump

Pump Type

AC Motor-Driven Centrifugal

Optional Motor Voltage Ratings

380 VAC, 400 VAC, and 415 VAC (50 Hz)
460 VAC and 575 VAC (60 Hz)

Motor, Power

7.45 kW (10 hp)

Backup Lube Oil Pump

Pump Type

DC Motor-Driven Centrifugal

Motor Voltage Rating

120 VDC

Motor, Power

7.45 kW (10 hp)

Lube Oil Cooler

Lube Cooler Oil Volume (Per Cooler)

Project Specific

Design Heat Load (Per Cooler)

Project Specific

Design Oil Flow Rate (Per Cooler)

Project Specific

Air Flow Rate

Project Specific, See Note (b)

Maximum Ambient Temperature

43°C (110°F)

Maximum Design Lube Oil Cooler Outlet
Temperature

66°C (150°F)

Maximum Lube Oil Cooler Design Pressure Drop

173 kPag (25 psig), See Note (c)

Minimum Lube Oil Cooler Design Pressure

1 035 kPag (150 psig)

Optional Motor Voltage Ratings

380 VAC, 400 VAC, and 415 VAC (50 Hz)
460 VAC and 575 AC (60 Hz)

Optional Motor, Power

7.5 kW (10 hp), 15 kW (20 hp), or 2 x 15 kW (20
hp)

Lube Oil Tank Immersion Heater, See Notes (d) and (e)

Optional Voltage Ratings

380 VAC, 400 VAC, and 415 VAC (50 Hz)
460 VAC and 575 VAC (60 Hz)

Power

3-Phase VAC, 40 kW

Minimum/Maximum Regulated Supply Pressure

100 to 225 psig (689 to 1551 kPag)

© 2008 Solar Turbines Incorporated. All rights reserved.

TPS250GS/908 - Preliminary

26