3.1.6 Part Numbering

The part number for the recorder is in the format as follows (See Fig 3.0 below for option location):

DC6

A

B

C

D

E

F

G

where each of the letters A through G has a meaning as follows:

A

Input Power:

1

-

100 to 240Vac 50/60Hz with cable and plug (Default - shown below)

2 - 18

– 30Vdc with Screw Terminals

3 -

100 to 240 Vac 50/60Hz with Screw Terminals

B

Input Channels:

06

– 6 Channels of Analog input (single row of connectors – default)

12 - 12 Channels of Analog input (dual row of connectors)

C

Output Options: 0

– None (Blank panel covers hole.)

1 -

6 Form A relay contacts 0.5A @ 200Vdc, 2 Control Inputs

2

- 12 Form A relay contacts 0.5A @ 200Vdc, 2 Control Inputs. (Shown below)

D

Serial Comms:

0

– None (Blank panel covers hole.)

1

– RS232/RS485 (9 Pin D sub) Serial Port (shown below)

E

Transmit Power: 0

– None (Blank panel covers hole.)

1

– 24Vdc 100mA isolated power output

F

Int. Memory:

1

– 512 Megabyte SD Card

2

– 1 Gigabyte SD Card

3

– 2 Gigabyte SD Card

G

FDA Compliance:

0

– Standard Unit

1

– FDA 21CFR11 Compliant Unit

The unit shown below in rear view has the part number DC6

1

–06–2–1–1–1–0

. (The additional 6

channels as would be in a 12 channel input recorder are shown grayed out).















Figure 3-0 Rear Panel showing ordering options

100

– 240 Vac 35VA

Advertising