Pull-type tongue hose, Two-cylinder shared supply circuit, Replace existing elbow – Great Plains YP925TD Assembly Instructions User Manual
Page 8: Install supply hoses
8
Flat Fold Marker
Great Plains Mfg., Inc.
113-870M
2012-22-03
Pull-Type Tongue Hose
For 2-point, 3-point and North American pull-type,
continue at “Install Cylinder Hoses” on page 10.
Refer to Figure 8
18. Select two new:
502-068D HYD HOSE CLAMP BRACKET
19. Where existing hoses are clamped to the tongue,
remove and save four sets:
802-159C HHCS 5/16-18X1 GR5
804-009C WASHER LOCK SPRING 5/16 PLT
20. Add the new clamps
to each clamp stack.
Loosely secure with the saved bolts and washers.
21. Route the new supply hoses under the new tap
clamps. Forward of the first clamp
leave the
same length of free hose as exists for the fan and
any lift hoses.
22. Secure the clamps. If the bolts
are too short,
replace them with locally provisioned
5
⁄
16
-16
fasteners, or use cable ties instead of clamps.
Continue at “Install Cylinder Hoses” on page 10.
Two-Cylinder Shared Supply Circuit
If the supply hoses are on a dedicated circuit, use the
instructions at “Dedicated Supply Circuit Hose” on
page 7. If the kit includes a cross (not a tee
), continue
at “Four-Cylinder Shared Supply Circuit” on page 9.
23. Select the two supply hoses
. See the table on
page 6 for the correct part number for the planter.
Replace Existing Elbow
Refer to Figure 9
24. Select two sets new:
811-078C TE 3/4MJIC
Remove any protective caps from the center port
and one end port.
25. Locate the existing elbows
. Perform the next
step separately for lift and lower hoses, to reduce
the risk of reversing the circuit at re-connection.
26. Remove one:
811-725C EL 90 3/4MJIC
Replace it with a tee
. The removed elbow is not
re-used.
27. Select two new:
811-150C EL 3/4FJIC 3/4MJIC
Remove any protective plug from the FJIC end of
the elbow
. Remove any protective cap remaining
on the tee
. Connect the elbow
to the tee, with
the MJIC end oriented up.
Install Supply Hoses
28. Remove any protective plug from one end of each
supply hose. Remove any protective cap from the
MJIC ends of elbows
. Connect one hose to each
elbow.
Continue at “Install Cylinder Hoses” on page 10.
Figure 8
Tongue Hose Routing
31800
13
50
19
1
50
13
19
50
1
Figure 9
2-Cylinder Shared Circuit
29937
73
22
75
High Pressure Fluid Hazard:
Ensure lift circuit pressure is zero. Wear gloves and safety
eyewear when working on hydraulics. Dangerous releases of
hydraulic fluid may occur if pressure remains in the circuit.
This could lead to serious personal injury. If hydraulic fluid
penetrates the skin, seek immediate medical attention from a
physician familiar with this type of injury.
13
73
S
73
22
22
73
75
75
73
75
75