Connect manifold to pump, Pre-delivery closeout – Great Plains YP825A Operator Manual User Manual

Page 165

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix B - Pre-Delivery

161

2014-08-15

Table of Contents

Index

401-651M

Connect Manifold to Pump

This page applies only to planters:
(YP425 s/n B1008N-)
(YP625 s/n B1043Q-) (YP825A s/n B1014S-)

Refer to Figure 144
47. Select one:

990-081R HOSE 3/4 ID 200PSI EPDM

and two:

800-123C CLAMP WRM DRV #16 SS (.68-1.5)

48. Slip a clamp

on each end of the hose

. Secure

one end to the elbow

at the manifold, and the

other to the

3

4

inch hose barb adaptor on the left

side of the valve cross fitting.

Refer to Figure 144 and Figure 145
49. Select one:

990-082R HOSE 1 ID 200PSI EPDM

and two:

800-123C CLAMP WRM DRV #16 SS (.68-1.5)

50. Route the hose as follows:

YP425A: directly from valve to pump
YP625A: along center tube and behind left tank
YP825A: along center tube and behind left tank

51. Slip a clamp

on each end of the hose

. Secure

one end to the 1in hose barb adaptor on the right
side of the valve cross fitting. Secure the other end to
the elbow at the top of the pump

.

If the customer has specified row connection points,
boom outlet orifice plates, nozzle caps and drop lines
may be installed at this time. See page 169.

Pre-Delivery Closeout

52. Check that all working parts are moving freely, bolts

are tight, and cotter pins are spread.

53. Check that all grease fittings are in place and

lubricated. See “Lubrication” on page 110.

54. Check that all safety decals and reflectors are

correctly located and legible. Replace if damaged.
See “Safety Decals” on page 6.

55. Inflate tires to pressure recommended and tighten

wheel bolts as specified. See “Tire Inflation Chart
on page 137.

56. For immediate delivery, move all uninstalled items

(such as the manuals, orifice plates and clean-out
container) from crates to the hoppers at the left side
of the planter. Otherwise, place them in a
well-marked container and store securely.

Figure 144

Manifold to Relief Valve (S/N-)

31035

64

76

77

64

64

1

77

64

64

77

1

76

64

Figure 145

Relief Valve to Pump (S/N-)

31031

64

76

2

64

76

2

Advertising
This manual is related to the following products: