Liquid fertilizer drop lines (option), Install caps on taps, Install drop lines to rows – Great Plains YP825A Operator Manual User Manual

Page 173: Install caps on taps install drop lines to rows

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix C - Initial Setup

169

2014-08-15

Table of Contents

Index

401-651M

Liquid Fertilizer Drop Lines (Option)

Booms are identical for single-row and twin-row planters.
For single-row use, and if planting single-row on a
twin-row planter, half of the nozzles are shut off.

Drop lines are not factory-installed, and may not be
dealer-installed, because there can be multiple possible
applicator connection points, including:

• frame-mounted coulter applicator

• 25AP Series nut bar applicator

• seed firmer applicator

• press wheel dribbler

Install Caps on Taps

Refer to Figure 156
1.

Determine which manifold taps

are to be active,

and which shut off.

2.

For each active row, select one:

832-051C NOZZLE CAP QUICK X 90X1/4 FNPT

Align the nozzle

with the manifold tube

. Press

down and rotate 90

°.

Note: Nozzles may face forward or back, at user

preference.

Note: Orifice plates

may be installed prior to capping, if

the size is known.

3.

For each shut-off row, select one:

832-042C

NOZZLE SHUT OFF CAP W/ GASKET

Press cap

down and rotate 90

°.

Install Drop Lines to Rows

Drop line tubing

is supplied on one or more uncut

coils:

990-109R TUBE NYLON 1/4OD X 062WL

Lengths are cut for each active nozzle.

4.

Route tubing and cut. Routing goals are:

5.

At the nozzle end, if the tubing adaptors are not
already installed, select one:

800-367C AD PUSH 1/4TUBEX1/4MNPT

Apply liquid pipe thread sealant. Thread the
adaptor

into the nozzle

.

Insert the drop line tube

into the adaptor

.

6.

At the application end, select one:

830-383C CP 1/4 PUSH LOK POLY

Confirm that the coupler

is required for, and

compatible with, the style of applicator. Push the
coupler

onto the applicator tube. Push the drop

line tube

into the coupler.

Note: When the coupler is not used, typically with

1

2

inch O.D. steel applicator tubes, push the drop

line tubing entirely through the applicator tube,
leaving

1

2

inch to

3

4

inch of tubing length

exposed. Tie wrap the tubing near the top of the
applicator tube.

Figure 156

Drop Line Detail

31002

74

1

75

3

2

78

65

73

1

75

75

2

3

74

74

• Allow slack at the nozzle for nozzle removal and

orifice plate changes.

• Route to avoid planter moving parts which could

cause tubing damage.

• Route for continuous down slope - avoid low spots

in tubing.

• Allow slack along the route to anticipate coulter or

row unit vertical range of motion.

• Secure the tubing with tie-wraps only where

planter operations can’t cause tubing movement.

78

78

65

65

75

78

65

73

73

73

78

Advertising
This manual is related to the following products: