Loading Liquid Fertilizer (S/N-)

If fertilizer will not be applied, remove the transmission
chain at the left end of the planter.

System Inspection
1.

Wear protective equipment suitable for the material
presently in or previously dispensed from the tank(s).

2.

Remove the lid on each tank and inspect for:
- residual fertilizer incompatible with next use
- contaminants
- debris that might clog filters
- trapped animals lost tools, etc.

3.

If it is necessary to flush a tank, or remove debris too
large to flush, see “Tank Clean-Out” on page 99.

4.

Re-secure each lid.

5.

At first use each season, and after extended use,
check the strainer mounted under the pump. Perform
any cleaning before loading fertilizer.

6.

The standard screen size is 80 (Blue). Some orifice
selections (step 9) require changing the strainer.

Tank Loading

Refer to Figure 25, and
Figure 132
on page 140 or Figure 133 on page 141
Review the information below before commencing steps.

• Load chemicals immediately prior to use. Material

loaded too early may sediment or stratify, resulting in
uneven application or system plugging.

• Load on level ground. Fill is uneven across a slope on

a dual-tank system. Unless valves are set to prevent it,
material can flow from one tank to another.

• The tank is designed to be loaded using the 2in CAM

quick-fill inlet (

), located at the left front of the

implement. If for any reason you cannot use that inlet,
you can also load material via a ladder and tank top
hatch. The lid is threaded and unscrews.

• Determine how to monitor tank fill level. If the day is

bright, or loading at night with a bright light available, it
is possible to see the fluid level through the
semi-translucent tank walls. Otherwise, it is necessary
to have an observer monitor through the tank hatch.

• Be familiar with the location of plumbing valves.

Common task require setting as many as five planter
valves (four with YP425A). See page 140 or page 141.

7.

Consult the Seed and Fertilizer Rate manual
(401-651B) for rate setting details.

8.

Set the Fertilizer drive sprockets and piston pump
rate adjuster per the Rate charts.

9.

Install the recommended size orifice plate at each
active drop line (Seed Rate manual).

11

13

12

Agricultural Chemical Hazard:
Avoid contact with skin or eyes. Wear proper protective
equipment as required by chemical manufacturer. Avoid
prolonged breathing of chemical fumes. Wear respirator as
required by chemical manufacturer. Some chemicals will cause
serious burns, lung damage, and death. Seek medical
assistance immediately if accident occurs. Know what to do in
case of accident.

Equipment Damage Risk:
Do not run the pump when dry. Remove the final pump drive
chain if not applying fertilizer. Air rapidly corrodes the pump.
When not pumping, fill the pump with clean water or RV
antifreeze.

Equipment Damage and Plugging Risks:
Use only materials compatible with polyethylene and
polypropylene. Use only pre-mixed liquid fertilizer. The system
is not designed for dry fertilizer mixes. Granular fertilizer may
damage the pump and plug orifices.

Equipment Damage Risk:
Do not leave fertilizer standing. Load late. Pump it all. Clean
out the system. Fertilizer is usually extremely caustic, and can
damage the piston pump if left standing. Also protect the pump
from air. See “Liquid Fertilizer Clean-Out” on page 99.

Note: Is it not possible to use the planter pump to load

material, as it only pumps when the planter is in
motion and is only plumbed to pump to the boom.
If the fertilizer source has no pump, it needs to be
elevated above the tank for gravity fill.

Figure 26

Quick-Fill Inlet (Valve Open) (S/N-)

31028