ADS FlowShark HV O&M Manual

23

Troubleshooting

The following tables contain general techniques for troubleshooting and resolving
problems that may occur with the FlowShark HV.

Problem

FlowShark HV will not turn on.

Possible

Causes

Battery voltage is too low.

Surrounding temperature is outside the specified operating
temperature.

Possible

Solutions

Recharge battery.

Warm or cool equipment.

Problem

Measurement value will not display or is fluctuating.

Possible

Causes

Sensor is not properly placed in flow or sensor cable is not
correctly connected into control unit.

Possible

Solutions

Check connections.

Reposition sensor in the flow.

Problem

Measurement value is too low and fluctuating heavily.

Possible

Causes

Reflective particles do not exist in an adequate
concentration in the flow.

Possible

Solutions

Choose another location for measurements.

Problem

Measurement value is too low/high and fluctuating heavily.

Possible

Causes

Significant turbulence exists in water.

Surrounding temperature is outside the specified operating
temperature.

Possible

Solutions

Recharge the battery.

Choose another location for measurements.