ADS XiLog+ System User Manual

45

Merge multiple days Choose this option to import data for

several days, and then designate the start and end dates representing
the date range for which to import the data using the Start Date and
End Date calendar controls.

Note: The calendar controls only allow the selection of dates for
which data is available. When multiple days are selected, the system
will average the data for each time period for every day in the range.
For example, to obtain the profile value for 2:00, the system will
average the data recorded at 2:00 for every day in the range.

3. Click on the Load Data button to import and display the data on a

graph.

Profile Alarms

To edit the profile data, click on the Auto Fit button. PrimeWorks places a
marker on the trace at each 15-minute interval to allow modification of the
value, if required.

Profile graph

If historical data is not available, click on the Reset button to set default
values for each profile value so that each one can be set independently.

To change a profile value, simply click on the graph marker and drag it to a
new location on the graph. Use the zoom & pan buttons to rescale the Y-axis
for the data displayed.

Selecting a profile value highlights the value on the graph and displays the
actual value in the Selected Value field. For greater accuracy, enter another
value in this field.

Disable a value, when necessary, by selecting the value and then clicking on
the Disable Selected Profile checkbox. When a value is disabled, XiLog+
will not generate alarms during the corresponding 15-minute period.