Network layout, Guideline maximum drop cable length – B&G H5000 Analogue Expansion User Manual

Page 16

Advertising
background image

16

|

System architecture |

H5000 Installation

Network layout

Guideline maximum drop cable length

For best performance it is recommended that drop cables (x) are kept
short. However in some cases it may be necessary to utilise longer
drops, in this case they should not exceed 6 meters.

Note:

The maximum cable length of the Micro-C network backbone

is 100 meters. For larger systems a network bridge should be
considered or use Mini-C cable for the network backbone which
would allow a maximum of 200 meters.

Backbone length is calculated by adding cable lengths a, b and c as
shown below.

Note:

Cable lengths a & c should not exceed 6 meters.

1

1

1

1

1

2

2

2

2

3

4

T

T

a

c

b

x

No.

Description

No.

Description

1

Network devices

3

Micro-C T-Joiner

2

Micro-C CAN bus
backbone

4

Micro-C 4-way connector

T

Micro-C Terminator

Advertising