BaseStation 1000 Quick Start Guide

Page 10

1000 uses this value to manage the number of zones that can run at one time so
that the water source is used as efficiently as possible. If you set this value to zero,
you cannot use this GPM amount to control concurrent zones.

High Flow Limit

Enter a flow limit for a running water source and then set up the system to shut
down the water source if that limit is exceeded.

Unexpected Flow Limit

Enter a flow limit for a water source that is turned off and then set up the system
to shut down the water source if that limit is exceeded.

Pipe Fill Time

To calibrate the Learn Flow process on the BaseStation 1000, you should enter the
pipe fill time before you initiate the Learn Flow. The pipe fill time is the number of
minutes that it takes to fill the empty line, activate the valve, and reach a steady
state operating pressure.

Enable/Disable

By default, the BaseStation 1000 enables all connected water sources. You can disable a
water source as needed and then re-enable it at another time.

Learn Flow Menu

Learn All Zones Screen

The controller runs one zone at a time to learn its flow. The learn flow cycle starts as soon as
you select the Learn All Zones option. Depending on how many zones are enabled on your
system, the learn flow cycle could take more than an hour to complete.

Learn One Zone Screen

Run a learn flow cycle for a specific zone.

Search & Assign Menu

After you have finished connecting all your devices, you need to have the controller find those
devices so you can assign them. Use the options under each of the following menus to assign and
set up the devices that you have connected to your controller.

Zone Menu

Device Assignment

Device Setup

MV/Pump Menu

Device Assignment