Cooper Instruments & Systems LTL 730 Wireless Tension Link Load Cell User Manual

Page 10

Advertising
background image

CF 150 LTL 730

7

12/08

Peak force and unit of measure on 2nd line
104.5 lbf
302.5 lbf


Format #3

Live force value plus unit of measure on 1st line
Peak force and unit of measure on 2nd line
Descriptive prefixes on each line
Force 104.5 lbf
Peak 302.5 lbf


Format #4

Fixed position output. Works well with RS-232 utilities, such as WedgeLink, for parsing into a
spreadsheet such as Microsoft Excel. (comma- separated).

Excel A B

1 104.5

lbf

2 302.5

lbf

Fixed characters.

Position Description
1-8

Live force number

10-16

Displayed unit of measure (up to 7 characters)

18-25

Peak force number

27-33

Displayed unit of measure (up to 7 characters)

9, 17, 26

Commas

34 Carriage

return

Example 1

<sp><sp><sp>104.5,<sp><sp><sp><sp>lbf, <sp><sp><sp>302.5,<sp><sp><sp><sp>lbf<CR>


Example 2 (custom unit)

<sp>140000.,<sp><sp><sp><sp><sp>kg,<sp>165450., ,<sp><sp><sp><sp><sp>kg<CR>


This would yield (shown in courier):

111111111122222222223333333333444444444455555555

123456789012345678901234567890123456789012345678901234567

104.5,

lbf,

302.5,

lbf,<CR>

140000.,

kg,

165450.,

kg,<CR>


Format #5

Live force, unit of measure, peak force, unit of measure. All tab separated.

104.5<tab>lbf<CR> (if presently displaying live readings)
302.5<tab>lbf<CR> (if presently displaying peak readings)
104.5<tab>lbf<tab>302.5<tab>lbf<CR> (if presently displaying dual mode)

Setup Misc

Press the Misc key to access the following soft key set (refer to Figure 4):
Flash

Press this soft key to enable or disable the “display flash” feedback. If enabled, the press of a key
causes the display to momentarily flash to give you a visual feedback that the key was activated.

Zero

Press this soft key enable or disable if a press of the Zero key also clears the Peak force value. If you
enable this function, press the Zero key to clear the Peak force and zero the load. If you disable the
function, the Zero key will only zero the load. Peak force remains in effect and will only be cleared
with the Clear function during operation.

Advertising