Manual advance regeneration check – EcoPure MW_MW30_450224 User Manual

Page 27

Advertising
background image

27

Miracle Water Installation & Operation Manual

NOTE:

Be sure water is in contact with the salt, and not separated by a salt bridge...
see page 23.

5. While in this diagnostic screen, the following information is available and may be beneficial for

various reasons. This information is retained by the computer from the first time electrical power is
applied to the face plate.

a. Press UP

to display the number of days this face plate has had electrical power applied.

b. Press DOWN . to display the number of regenerations initiated by this face plate since the LE
code number was entered.

6. Press and hold the (Select/Menu) button until LE31 shows in the display.

SELECT

MENU

This code identifies the softener model. If the wrong number shows, the softener will operate on
incorrect programming.

7. Return the present time display — Press the (Select/Menu) button.

8. To change LE number — Press the UP

or DOWN . button until the correct LE code shows.

Then, press the (Select/Menu) button to return to the present time display.

SELECT

MENU

SELECT

MENU

Manual Advance Regeneration Check

This check verifies proper operation of the valve motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make the initial checks, and the manual initiated diag-
nostics.

NOTE:

The faceplate display must show a steady time (not flashing). If an error code shows, first
press the (Select/Menu) button to enter the diagnostic display.

1. Press the (Recharge) button and hold in for 3 seconds. RECHARGE begins to flash as

the softener enters the fill cycle of regeneration. Remove the brinewell cover and, using a flashlight,
observe fill water entering the tank.

a. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine

tubing, or brine valve riser pipe.

2. After observing fill, press the (Recharge) button to move the softener into brining. A slow

flow of water to the drain will begin. Verify brine draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable drop in the liquid level.

NOTE: Be sure a salt bridge is not preventing water with salt contact.

a. If the unit does not draw brine, check for (most likely to least likely)

- Dirty or defective nozzle and venturi, page 23

- Nozzle and venturi not seated on the gasket, or gasket defective

- Restriction in valve drain, causing a back-pressure (bends, kinks, elevated too high, etc.),

installation Step 6 on page 14

- Obstruction in brine valve or brine tubing

- Inner valve failure (obstructed outlet disc, wave washer defective, etc.)

NOTE:

If water system pressure is low, an elevated drain hose may cause back pressure, stopping
brine draw.