Manual_EtherCAT_PoE_BIDE_EN.doc 11/19

Baumer IVO GmbH & Co. KG

11.11.10

Villingen-Schwenningen,

Germany

Object 0x1A00 TxPDO1 Mapping

SubIndex 0
Data type

Unsigned 8

Access ReadOnly
Default
EEPROM No
Significance Maximum supported subindex
Values 3

SubIndex 1
Data type

Unsigned 32

Access ReadOnly

Default
EEPROM No
Significance Position

value

Values 0x6004

SubIndex 2
Data type

Unsigned 16

Access ReadOnly

Default
EEPROM No
Significance Warnings
Values 0x6505

SubIndex 3
Data type

Unsigned 32

Access ReadOnly

Default
EEPROM No
Significance System

time

Values 0x2000


Device-specific objects

Object 0x6000 Operating parameters

SubIndex 0
Data type

Unsigned 16

Access ReadWrite
Default

0 , scaling OFF, CW

EEPROM Yes
Significance Operating

parameters

Values

Bit 0: direction of rotation

0 CW
1 CCW

Entries ≠ default values are only effective with enabled scaling function (0x6000).

Bit 2: scaling function ON/OFF (firmware version V4.00 and up)

0 scaling disabled. Encoder provides raw data (less offset).
1 scaling enabled. Encoder provides position values under consideration of scaling factor
and offset ².

Example: Value 0x0004 -> scaling on, CW

² Firmware version (0x100A) V4.00 and up provide here an optional scaling function, otherwise customer-
specific parameterization as resolution, total measuring range, direction of rotation and preset are not
effective.

Above parameters are first saved volatile in the encoder RAM. If required, non-volatile saving in EEPROM is by
utilizing object SAVE Application parameter (0x1010).
Please note that with enabled scaling the input data (TxPDO) are generated considerably more slowly since the
encoder requires additional processing time for scaling calculations. In other words, the programmed PLC cycle times
for encoder readout have to be correspondingly prolonged.