6.3 Display

elements


6.3.1 State

indicator

The bus cover provides a DUO LED (green/red) operating in line with EtherCAT Indicator Specification
V0.91.

DUO-LED green RUN State

RUN State

Status

Description

Category

Off

INIT

The device is in state INIT

Mandatory

Blinking

PRE-OPERATIONAL

The device is in state PRE-OPERATIONAL

Mandatory

Single Flash

SAFE-OPERATIONAL

The device is in state SAFE-OPERATIONAL

Mandatory

On

OPERATIONAL

The device is in state OPERATIONAL

Mandatory

Flickering

INITIALISATION or
BOOTSTRAP

The device is booting and has not yet entered the INIT
state, or:The device is in state BOOTSTRAP.Firmware
download operation in progress

Optional

Double Flash

Reserved

Reserved for future use

reserved

Triple Flash

Reserved

Reserved for future use

reserved

Quadruple

Reserved

Reserved for future use

reserved

DUO-LED red ERR State

ERR State

Error

Description

Example

Category

Off

No error

The EtherCAT
communication of the
device is in working
condition

Mandatory

Flickering

Booting Error Booting

Error was detected. INIT
state reached, but
Parameter "Change" in the
AL status register is set to
0x01:change error

Checksum Error in Flash
Memory.

Optional

Blinking

Invalid Configuration

General Configuration Error

State change commanded
by master is impossible due
to register or object settings.

Mandatory

Single Flash

Unsolicited State
Change

Slave device application
has changed the EtherCAT
state autonomously:
Parameter "Change" in the
AL status register is set to
0x01:change/error.

Synchronisation Error,
device enters Safe-
Operational automatically.

Mandatory

Double Flash

Application Watchdog
Timeout

An application watchdog
timeout has occurred.

Sync Manager Watchdog
timeout

Mandatory

Triple Flash

Reserved

Reserved for future use

Reserved

Quadruple Flash Reserved

Reserved for future use

Reserved

On

PDI Watchdog
Timeout

A PDI Watchdog timeout
has occurred

Application controller is not
responding any more

Optional



6.3.2 Link/Activity

indicator

One LED each for input and output.

Link

Activity

State of Link/Activity indicator

Yes No

On

Yes Yes

Flickering

No Not

applicable

Off



Note: All LED´s are “off“ if the encoder is under power supply but not yet connected to Ethernet.