4.5.2. N 155 reset to default „Q“ (51h)

This command is for resetting several parameters to default, either by individual or collective reset.

Data = q (71h) = reset parameters to default

Data = t (74h) = reset device identifier to 98.

Data = x (78h) = reset current value (lower line of display) to 0

Data = ∆ (7Fh) = all above functions except „r“ (72h) are accomplished.


Note: No profile reset. Profile reset by command „R“.

Example 1: Reset N 155 to default

SOH

Adr

Cmd

Data

EOT

CRC

Send

01h

20h

51h

7Fh

04h

AEh

SOH

Adr

Data

EOT

CRC

Response

01h

20h

6Fh

04h

52h N 155 replies by standard response ‚o’ (6Fh) = OK


Example 2: Reset all N 155 to default by broadcast command (Adr=99)

SOH

Adr

Cmd

Data

EOT

CRC

Send

01h

83h

51h

7Fh

04h

B3

Response

no confirmation


4.5.3. Profile reset of the target display „K“ (4Bh)

This command is clearing all prior profiles.

Example 1: Profile reset in a specific N 155

SOH

Adr

Cmd

Data

EOT

CRC

Send

01h

20h

4Bh

7Fh

04h

C6h

SOH

Adr

Data

EOT

CRC

Response

01h

20h

6Fh

04h

52h N 155 standard reply ‚o’ (6Fh) = OK

Example 2: Profile reset with all N 155 by broadcast command (Adr=99)

SOH

Adr

Cmd

Data

EOT

CRC

Send

01h

83h

4Bh

7Fh

04h

DBh

Response

No confirmation

Important: After profile reset all profile data are set to auf FFFFFFhex respectively FFhex (current profile
number). The display will show 5 dashes instead of the target.