Error signals, Overview of commands, 1 crc error – Baumer N 155 User Manual

Page 16: 2 format error

Advertising
background image

N 155

www.baumer.com

16

5. Error signals

5.1 CRC

error

If the target display recognises a CRC error in a command transferred, the following signal will be replied:

SOH

Adr

Error EOT

CRC

Response

01h

20h

65h

04h

46h Error = „e“ (65h) = CRC error


5.2 Format

error

If the target display recognises a format error i.e. volume of protocol incorrect or invalid command (Cmd); the fol-
lowing signal will be replied:

SOH

Adr

Error EOT

CRC

Response

01h

20h

66h

04h

40h Error = „f“ (66h) = Format error



6. Overview of commands

The following chart is showing in alphabetical order all possible commands (Cmd) as well as options regarding
read and write (programming) etc.

Command

code

Data volume

in bytes

Read

Write

Broadcast Significance

a (61h)

5

X

X

-

Read/write general parameters

i (69h)

1

X

X

X

Parameter: mm / inch

t (74h)

6

-

X

-

Send tool number

u (75h)

6

-

X

-

Send any number sequence

A (41h)

2

X

X

X

Place or indicate device identifier

C (43h)

3

X

-

-

Check current value = target

K (4Bh)

-

-

X

X

Profile reset

Q (51h)

1

-

X

X

Specific command: reset N 155

R (52h)

6

X

X

-

Read/write current value

S (53h)

8

X

X

-

Read/write target

U (55h)

6

X

X

-

Offset

V (56h)

2

X

X

X

Read/write profile number

X (58h)

4

X

-

-

Specific command: read version number