Baumer N 155 User Manual
Page 9
N 155
www.baumer.com
9
4.2.7 Write a number sequence in the lower line of the display „u“ (75h)
The command is for writing a 5-digit number sequence in the lower display line. The sequence is depicted with-
out dot respectively comma. Preceding zeroes as well as both direction arrows are hidden. The upper line is still
showing the current target or number sequence.
The number sequence will remain until any command except „t“, „u“ or „R“ is received by the interface.
Example: (number sequence = 012345)
SOH
Adr
Cmd
Number sequence = 012345
EOT
CRC
send
01h
20h
75h
30h
31h
32h
33h
34h
35h
04h
B6h
SOH
Adr
Cmd
Number sequence = 012345
EOT
CRC
response
01h
20h
75h
30h
31h
32h
33h
34h
35h
04h
B6h
Important:
Combining the commands „t“ and „u“ enables a 10-digit number in the display.
Both number sequences are not saved by EEPROM.