3 read / write profile number „v“ (56h), 4 check position „c“ (43h) – Baumer N 155 User Manual

Page 7

Advertising
background image

N 155

www.baumer.com

7

Example 2: Read target of a specific profile (profile number = 17; target = 12.50)

SOH

Adr

Cmd Profil-Nr. = 17

EOT

CRC

Send

01h

20h

53h

31h

37h

04h

16h

SOH

Adr

Cmd Profil-Nr. = 17

target = 12.50

EOT

CRC

Response

01h

20h

53h

31h

37h

30h

30h

31h

32h

35h

30h

04h

BCh


Example 3: Write target of specific profile (profile number = 17; target = -12.50)

s

SOH

Adr

Cmd Profil-Nr. = 17

target = -12.50

EOT

CRC

Send

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh

SOH

Adr

Cmd Profil-Nr. = 17

target = -12.50

EOT

CRC

Response

01h

20h

53h

31h

37h

2Dh

30h

31h

32h

35h

30h

04h

FBh


4.2.3 Read / write profile number „V“ (56h)

This command is for reading the number of the presently active profile respectively for altering the profile.

Example 1: Read active profile (active profile number = 38)

SOH

Adr

Cmd

EOT

CRC

Send

01h

20h

56h

04h

20h

SOH

Adr

Cmd Profile no. = 38 EOT

CRC

Response

01h

20h

56h

33h

38h

04h

28h

Response after reset upon clearing all profiles:

SOH

Adr

Cmd Profile no. = FF EOT

CRC

Response

01h

20h

56h

3Fh

3Fh

04h

16h


Example 2: Send new profile (New profile number = 17)

SOH

Adr

Cmd Profile no. = 17 EOT

CRC

Send

01h

20h

56h

31h

37h

04h

3E

SOH

Adr

Cmd Profile no. = 17 EOT

CRC

Response

01h

20h

56h

31h

37h

04h

3E


Example 3: Send new profile by broadcast command to each N 155 (Adr = 99 (83h); new profile number = 17)

SOH

Adr

Cmd Profile no. = 17 EOT

CRC

Send

01h

83h

56h

31h

37h

04h

04

Response

No confirmation

To check whether the new profile has been entered by all N 155 in the network, check command „C“ (43h) can
be applied.

4.2.4 Check position „C“ (43h)

This command is providing the alignment status of target versus current value. If current value is in coincidence
with target the response will be „o“ (6Fh) for OK together with the current profile number. If the running value is
beyond the target, „x“ (78H) followed by the current profile number will be replied.

Example: (active profile number = 05)

SOH

Adr

Cmd

EOT

CRC

Send

01h

20h

43h

04h

0Ah

Response if current value = target:

SOH

Adr

Cmd Status Profile no. = 05 EOT

CRC

Response

01h

20h

43h

6Fh

30h

35h

04h

A5h

Response if current value

≠ target:

SOH

Adr

Cmd Status Profile no. = 05 EOT

CRC

Response

01h

20h

43h

78h

30h

35h

04h

1D


Advertising