Example load schedule with panel terminations – Crestron electronic Residential Lighting User Manual

Page 14

Advertising
background image

Crestron Residential Lighting Design Guide

Specifying a Lighting System

Doc. 5999F

9

Example Load Schedule with Panel Terminations

Area

Room

Controlled Ckt

Name

Controlled

Ckt No.

Fixture

Load Type

Dim Emergency

Fixture

Watts

Fixture

Qty

Total

Watts

Enclosure

Slot

Module

Output

Main Floor Bathroom 1

Downlights

009

Downlights

Incandescent

yes no 100 1 100 Enclosure

1

2

CLX-1DIM8

1

Main Floor Bathroom 1

Downlights 2

008

Downlights

Incandescent

yes

no

100

2

200

Enclosure 1

2

CLX-1DIM8

2

Main Floor Bathroom 1

Downlights 3

006

Downlights

Incandescent

yes no 100 2 200 Enclosure

1

2

CLX-1DIM8

3

Main Floor Bathroom 1

Drapes

019

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-1MC4

1

Main Floor Bathroom 1

Exhaust Fan

007

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A

Interface 2

1

Main Floor Bathroom 2

Downlights

011

Downlights

Incandescent

yes

no

100

1

100

Enclosure 1

2

CLX-1DIM8

4

Main Floor Bathroom 2

Downlights 2

010

Downlights

Incandescent

yes no 100 3 300 Enclosure

1

2

CLX-1DIM8

5

Main Floor Bathroom 2

Drapes

021

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-1MC4

2

Main Floor Bathroom 2

Exhaust Fan

012

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A

Interface 4

1

Main Floor

Bedroom

Ceiling Fan

022

Ceiling Fan

Ceiling Fan

no

no

100

1

100

Enclosure 1

6

CLX-1FAN4

1

Main Floor

Bedroom

Downlights

005

Downlights

Incandescent

yes no 250 2 500 Enclosure

1

2

CLX-1DIM8

7

Main Floor

Bedroom

Downlights 2

004

Downlights

Incandescent

yes

no

100

4

400

Enclosure 1

3

CLX-1DIM4

1

Main Floor

Bedroom

Downlights 3

003

Downlights

Incandescent

yes

no

100

1

100

N / A

N / A

Interface 6

1

Main Floor

Bedroom

Downlights 4

002

Downlights

Incandescent

yes

no

100

1

100

N / A

N / A

Interface 5

1

Main Floor

Bedroom

Downlights 5

001

Downlights

Incandescent

yes no 100 2 200 Enclosure

1

3

CLX-1DIM4

2

Main Floor

Bedroom

Drapes

018

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-1MC4

3

Main Floor

Bedroom

Drapes 2

017

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-1MC4

4

Main Floor

Bedroom

Drapes 3

016

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-1MC4

1

Main Floor

Foyer

Downlights

013

Downlights

Incandescent

yes no 100 4 400 Enclosure

1

2

CLX-1DIM8

6

Main Floor

Sauna

Drapes

020

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-1MC4

2

*Calculation of load wattage includes transformer loss.