Load schedule with panel terminations, Residential lighting design guide appendix a – Crestron electronic Residential Lighting User Manual

Page 68

Advertising
background image

Residential

Lighting

Design

Guide

Appendix A

Doc. 5999F

63

Load Schedule with Panel Terminations

Project: Example Residence

Dealer: Crestron

Creator: Crestron D3 Pro v2.3.7

Description:

Date: 11/4/2003 System Number: 1

Area

Room

Controlled Ckt

Name

Controlled

Ckt No.

Fixture

Load Type

Dim Emergency

Fixture

Watts

Fixture

Qty

Total

Watts

Enclosure

Slot

Module Output

Main
Floor

Bathroom

1

Downlights 009

Downlights

Incandescent

yes

no 100

1 100

Enclosure

1

2

CLX-

1DIM8

1

Main
Floor

Bathroom

1

Downlights 2

008

Downlights Incandescent

yes

no

100

2

200

Enclosure 1

2

CLX-

1DIM8

2

Main
Floor

Bathroom

1

Downlights 3

006

Downlights Incandescent

yes

no

100

2

200

Enclosure 1

2

CLX-

1DIM8

3

Main
Floor

Bathroom

1

Drapes

019

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

1MC4

1

Main
Floor

Bathroom

1

Exhaust Fan

007

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A Interface

2

1

Main
Floor

Bathroom

2

Downlights

011

Downlights Incandescent

yes

no

100

1

100

Enclosure 1

2

CLX-

1DIM8

4

Main
Floor

Bathroom

2

Downlights 2

010

Downlights Incandescent

yes

no

100

3

300

Enclosure 1

2

CLX-

1DIM8

5

Main
Floor

Bathroom

2

Drapes

021

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

1MC4

2

Main
Floor

Bathroom

2

Exhaust Fan

012

Exhaust Fan

Switched

no

no

200

1

200

N / A

N / A Interface

4

1

Main
Floor

Bedroom

Ceiling Fan

022

Ceiling Fan

Ceiling Fan

no

no

100

1

100

Enclosure 1

6

CLX-

1FAN4

1

Main
Floor

Bedroom Downlights

005 Downlights

Incandescent

yes no 250 2 500

Enclosure

1

2 CLX-

1DIM8

7

Main
Floor

Bedroom

Downlights 2

004

Downlights Incandescent

yes

no

100

4

400

Enclosure 1

3

CLX-

1DIM4

1

Main
Floor

Bedroom Downlights

3

003 Downlights

Incandescent

yes

no

100

1

100

N / A

N / A Interface

6

1

Main
Floor

Bedroom

Downlights 4

002

Downlights Incandescent

yes

no

100

1

100

N / A

N / A Interface

5

1

Main
Floor

Bedroom

Downlights 5

001

Downlights Incandescent

yes

no

100

2

200

Enclosure 1

3

CLX-

1DIM4

2

Main
Floor

Bedroom

Drapes

018

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

1MC4

3

Main
Floor

Bedroom

Drapes 2

017

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

4

CLX-

1MC4

4

Main
Floor

Bedroom

Drapes 3

016

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-

1MC4

1

Main
Floor

Foyer Downlights 013 Downlights

Incandescent

yes no 100 4 400

Enclosure

1

2 CLX-

1DIM8

6

Main
Floor

Sauna

Drapes

020

Drapes

3-Wire Motor

no

no

200

1

200

Enclosure 1

5

CLX-

1MC4

2

*Calculation of load wattage includes transformer loss.

The following three pages contain the complete application diagrams of this example
system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up to
fit the space available. The complete diagram is available on line at:

http://www.crestron.com/dealer-tech_resources/application_diagrams.asp

.