B. Emergency Operation Methods

X: Operation possible
–: Operation not possible

Error

Message on display

OES

Steam

Combi

Hot

Air

Retherm

Cook

&

Hold

Delta-

T

E01

Not enough water

X

--

--

up to

356°F

--

X

X

E02

Connection area temp.

too high

X

X

up to 284°F

up to

284°F

up to

284°F

up to

284°F

up to

284°F

E04

Connection area fan

malfunction

X

X

up to 284°F

up to

284°F

up to

284°F

up to

284°F

up to

284°F

E11

Excess oven

temperature

--

--

--

--

--

--

--

E15

Excess temperature of

condenser

X

--

--

up to

356°F

--

X

X

E33

Core temp. sensor

faulty

X

X

X

X

X

X

X

E36

Condenser sensor

failure

X

X

(2)

up to 356°F

(2)

up to

356°F

(2)

up to

356°F

(2)

X

(2)

X (2)

E 29

Error in ground

connection

--

--

--

--

--

--

--

E80

ID error

--

--

--

--

--

--

--

E81

Program memory error

X

X

X

X

X

X

X

E82

Working parameter

error

X

X

X

X

X

X

X

E83

Algo. error

X

X

X

X

X

X

X

E89

I2C error

X

X

X

X

X

X

X

NOTES: