4. Save Snapshot Configuration file and Load Snapshot Configuration file: The Snapshot

Debugger tool has options to save the Snapshot configuration file and to load the

previously saved configuration file. Below is the table which depicts the functionality of

these two options:

Table 4: Snapshot view of toolbar options to save and load configuration files

Icon

Action

IR Bits Before Device

Save configuration

Saves the current settings of the Snapshot view to a text file

(default filename is *.Snapshot). User can also give the

specific file name for the configuration file to be saved. All

GUI inferred settings will be saved in this file.

Load configuration

The Snapshot debugger loads a previously saved

configuration file.

5. Collecting Samples of the design: In the Snapshot Debugger tool there are two ways to

collect the samples: The first is in the LOG-File and the other is in the Waveform File.

“Log File” sets the file name for the log file from “Arm” of the Snapshot Debugger Tool.

The Browse button allows for the selection of a location different from the default

(./Snapshot.log). If an error occurs during setup or while reading back the sample

information, the Snapshot log file will contain the error messages. The user can visit these

error messages and fix the appropriate setting to “Arm” Snapshot Debugger Tool again.

“Waveform File” sets the file name for storing downloaded samples’ waveform

information from the Snapshot Debugger in VCD format. The Browse button allows for

the selection of a location different from the default (./Snapshot.vcd). The significance of

this VCD file is that the user can load this VCD file into any 3rd party simulation tool and

view the signals of the user design.

UG016, September 22, 2014