TROUBLESHOOTING

MOTOR HEAD SAFETY CUT-OFF

The mixer is equipped with a motor head
safety cut-off . If the mixer head is lifted up at
any time while the mixer motor is switched
on, the safety cut-off will automatically
switch the motor off and set the mixer into
standby mode.
To restart the motor within 5 minutes, lower
the mixer head into the horizontal (closed)
position, and turn the dial away then back to
the required speed setting. This will resume
mixing and the timer will resume counting.
To restart the motor after 5 minutes or more,
lower the mixer head and turn the dial to OFF
then back to the required speed. The timer
will start from 0.
To turn the mixer off (instead of restarting),
turn the dial to OFF, and unplug from the
wall.

ELECTRONIC PROTECTION CUT-OFF
(current overload)

The mixer is equipped with an electric
protection cut-off and will automatically
stop operating if the motor is stalled or
overloaded. This is normally a result of
excessive ingredients being processed at one
time. Should the mixer go into this mode, the
LED indicator band will fl ash and the error
message “E1” will fl ash on the LCD screen and
the buzzer will “beep” 3 times.

If this error occurs, turn the speed control
dial to the OFF position, switch the appliance
off at the power outlet and unplug the cord.
Remove some of the ingredients in the
mixing bowl and then restart the mixer.

THERMO PROTECTION CUT-OFF
(temperature overload)

The mixer is equipped with a self-resetting
safety device which safeguards against
overheating the motor with excessive
loads. If overheating occurs, the mixer will
automatically activate the overheating
protection device and the motor will switch
itself off . Should the mixer go into this mode,
the LED indicator band will fl ash and the
error message “E2” will fl ash on the LCD
screen and the buzzer will “beep” 3 times.

If this error occurs, turn the speed control dial
to the ‘OFF’ position, switch the appliance
off at the power outlet and unplug the cord.
Wait at least 15 minutes before restarting the
mixer.