Power Supply Requirements

The Air Handler is a high performance cooling system and with significant power
requirements. Each of the two sections of the unit, evaporator and condenser, requires
its own power source or cord. The amps and watts for the configurations are listed
below.

AH6500 / AH6500S Cord Connected

Evaporator Module

Condenser Module

System

Amps

(FLA)

@ 115V /

60HZ

Breaker

Size

Power

Input

Watts

Amps

(FLA)

@ 115V /

60HZ

Compressor

LRA

Breaker

Size

Power

Input

Watts

Total

Power

Input

Watts

Standard

5.6

15

640

11.46

53.0

25

824

1464

With Humidifier

6.6

15

755

11.46

53.0

25

824

1579

With Heating

10.6

15

1220

11.46

53.0

25

824

1579

AH8500 / AH8500S Cord Connected

Evaporator Module

Condenser Module

System

Amps

(FLA)

@ 115V /

60HZ

Breaker

Size

Power

Input

Watts

Amps

(FLA)

@ 115V /

60HZ

Compressor

LRA

Breaker

Size

Power

Input

Watts

Total

Power

Input

Watts

Standard

5.6

15

640

11.4

54.5

25

958

1598

With Humidifier

6.6

15

755

11.4

54.5

25

958

1713

With Heating

10.6

15

1220

11.4

54.5

25

958

1713

AH6500S Permanently Connected

Evaporator Module

Condenser Module

System

Amps

(MCA)

@ 115V /

60HZ

Breaker

Size

Power

Input

Watts

Amps

(MCA)

@ 115V /

60HZ

Compressor

LRA

Breaker

Size

Power

Input

Watts

Total

Power

Input

Watts

Standard

3.5

15

320

17.1

53.0

25

1144

1464

With Humidifier

4.5

15

435

17.1

53.0

25

1144

1579

With Heating

11.3

15

1220

17.1

53.0

25

1144

1579

AH8500S Permanently Connected

Evaporator Module

Condenser Module

System

Amps

(MCA)

@ 115V /

60HZ

Breaker

Size

Power

Input

Watts

Amps

(MCA)

@ 115V /

60HZ

Compressor

LRA

Breaker

Size

Power

Input

Watts

Total

Power

Input

Watts

Standard

3.5

15

320

16.9

54.5

25

1278

1598

With Humidifier

4.5

15

435

16.9

54.5

25

1278

1713

With Heating

11.3

15

1220

16.9

54.5

25

1278

1713

Notes:
1. Electrical ratings are for evaporator and condenser fans set on high speed.

2. Two dedicated non-GFI power supply circuits are required, one for each module.