Up and Down Buttons

To view the “High Temp” recorded by the cooling
unit, press the “Up” button once.

To view the “Low Temp” recorded by the cooling
unit, press the “Down” button once.

To reset the “High Temp” or “Low Temp”, press
the “Set” button for three seconds while “Hi” or
“Lo” is displayed. “RST” will blink three times to
indicate confirmation.

Set Button

The cooling unit is factory preset with a Minimum
Set Point of 58°F and a Temperature Differential
of 4°F. This means that the cooling unit will turn
on when the display rises above 62°F (58°F +
4°F), and turn off when the display falls below
58°F. In this example, the average temperature
inside the cellar will be 60°F.

To view the Minimum Set Point, press the “Set”
button for one second.

To change the Minimum Set Point,

Press the “Set” button for three seconds
until °F” blinks

Press “Up” or “Down” button

Press “Set” button to confirm

The “Set” temperature will blink three times to
indicate confirmation

The recommended Minimum Set Point range is
53 - 60°F. To change the Temperature
Differential, see “Advanced Operation” later in
this chapter.